The LNJAMI LJMJ series anti-glare classroom lights come in 12 models with 5000K neutral white and a color rendering index above 95. Grille or micro-prism optics control glare, and an uplight design brightens the ceiling for even, comfortable classroom lighting. Suspended and recessed versions are available, and the range can be laid out to meet China's mandatory classroom lighting standard GB 7793-2025, which requires a maintained average illuminance of at least 300 lx on desks with a uniformity of at least 0.7.
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
- Grille / micro-prism anti-glare: the light source sits behind a grille or micro-prism diffuser, so students looking up at the board or down at their books are not dazzled — less eye strain over a long school day.
- Uplight design: suspended models also light the ceiling, avoiding the “bright desk, dark room” effect and giving the whole classroom consistent light.
- High color rendering, CRI >95: text, color illustrations and board writing look true to life — well above the CRI ≥80 required by the standard.
- 5000K neutral white: within the 3300K–5300K range set by GB 7793-2025; bright and clear without a harsh cold-white feel, helping students stay focused.
- Complete range: LJMJ-101/102/103 are 1200×300 mm suspended fixtures; LJMJ-104/105/106 are recessed panels that fit standard 600 mm modular ceilings, so retrofits need no ceiling work.
- Higher-output option: LJMJ-101-12 is rated 42W for classrooms with higher ceilings or higher illuminance targets.
- Energy saving, long life: LED light source uses less power than fluorescent tubes and needs little maintenance.
| Model | Name | Size | Power | CCT | CRI | Optics | Mounting |
|---|---|---|---|---|---|---|---|
| LJMJ-101 | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-101-1 | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-101-12 | Anti-Glare Classroom Light | 1200×300 mm | 42W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-102 | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-102-1 | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-102-2 | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-103 | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Micro-prism + uplight | Suspended |
| LJMJ-103-A | Anti-Glare Classroom Light | 1200×300 mm | 36W | 5000K | >95 | Micro-prism + uplight | Suspended |
| LJMJ-103-3 | Anti-Glare Smart Office Light | 1200×300 mm | 36W | 5000K | >95 | Grille + uplight | Suspended |
| LJMJ-104 | Anti-Glare Classroom Panel Light | 600×600×33 mm | 36W | 5000K | 95 | Anti-glare diffuser | Recessed |
| LJMJ-106 | Anti-Glare Classroom Panel Light | 595×595×33 mm | 36W | 5000K | 95 | Anti-glare diffuser | Recessed |
| LJMJ-105 | Anti-Glare Classroom Panel Light | 600×1200×33 mm | 36W | 5000K | 95 | Anti-glare diffuser | Recessed |
GB 7793—2025, Hygienic Standard for Daylighting and Artificial Lighting for Primary and Middle School Classrooms, is China's mandatory national standard, in force since November 1, 2026 and replacing the 2010 edition.
| Requirement | GB 7793-2025 | LJMJ Series |
|---|---|---|
| Correlated color temperature | 3300K–5300K | 5000K |
| General color rendering index Ra | ≥80 | >95 (panels: 95) |
| Desk maintained illuminance / uniformity | ≥300 lx / ≥0.7 | Achievable with a proper layout for the room size |
| Light source | No bare light sources | Grille / micro-prism / diffuser shielded |
| Mounting height | Lowest luminous surface ≥1.7 m above desks | Suspension length adjustable on site |
Note: actual illuminance and uniformity depend on fixture quantity, mounting height and layout; acceptance is based on on-site measurement.
- For a typical classroom of about 9 m × 7 m, 9 classroom lights (3 rows × 3) plus 2–3 LJMH blackboard lights is a common configuration — confirm with an illuminance calculation.
- Run the long axis of the fixtures perpendicular to the blackboard to reduce direct glare in students’ line of sight.
- Keep the lowest luminous surface at least 1.7 m above the desks; in rooms with ceiling fans, keep fixtures clear of the blade height.
- Put the row next to the windows on its own switch to make use of daylight and save energy.
Primary and secondary school classrooms, multimedia classrooms, lecture halls, libraries, art and calligraphy rooms, laboratories, teachers’ offices, meeting rooms and training centers.
- Send us your classroom and board dimensions plus ceiling height — we will help with the fixture layout and an illuminance calculation.
- Samples are available for testing. Suitable for new school buildings, classroom lighting upgrades and education equipment procurement.
Lighting a whole classroom? See also our LJMH LED blackboard lights, or contact us directly.












